Reconstruction when no photograph shows the floor
The reconstruction takes the up direction and the height zero from the floor. The earlier release required floor points in at least three photographs (or in every photograph when there are fewer), so a set with one photograph that misses the floor failed, and a single photograph without floor forced the agent to mark a floor that was not there. This page shows the change of 2026-11-25 and every run made to check it.
What changed
- A photograph that does not show the floor gets no floor points. There is no minimum number of photographs with floor.
- When no photograph shows the floor, no floor is built. The up direction comes from another flat surface the agent marks in the same call (a flat ceiling, a table top, an upright wall), else from how the photographs were held. The exported scene carries
scene_frame.floor_observed: false. - In a scene without floor the automatic camera path flies at the height of the photographs and looks up or down as they do.
Every run
Up-direction error: the angle between the up direction of the run and that of the reconstruction from all photographs of the same scene. All runs use the camera poses of the benchmark.
| Input | Earlier release | After the change | Up direction taken from |
|---|---|---|---|
| Meeting room, 3 photographs (one shows no floor) | failed: floor points were required in all three photographs | 0.9° | floor, marked in two photographs |
| Church, 1 photograph, no floor in view | 169.8° (upside down) | 4.9°, 5.6°, 4.8° (three runs) | flat ceiling |
| Meeting room, 1 photograph, no floor in view | 173.7° (upside down) | 28.2°, 1.1°, 66.3° (three runs) | a surface the agent took for a flat ceiling |
The single photograph of the meeting room is not solved: the result depends on which surface the agent marks (last section).
Church, one photograph
The photograph looks up 24° and shows the ceiling, two walls and the altarpiece. The reconstruction has no floor. One chunk generated along an automatic path.

Reconstruction: point cloud and boxes
Meeting room, three photographs
The third photograph shows the roof and the top of the walls. The floor points (yellow) come from the other two, which the earlier release rejected.

Photograph 1: floor points marked

Photograph 2: floor points marked

Photograph 3: no floor in view, no points
Reconstruction: point cloud and boxes
Meeting room, one photograph: not reliable
The same photograph in three runs. The agent is asked for a flat level ceiling and marked a different surface each time (yellow). Only the flat soffit gives the right direction. Without any marked surface, the direction in which the photograph was held is 17.7° off for this photograph (19.6° for the church).

Run 1, first wording of the instruction: a sloping roof panel. Up-direction error 28.2°.

Run 2, final wording: the flat soffit. Up-direction error 1.1°.

Run 3, final wording, another run: an upright face below the roof. Up-direction error 66.3°.
Not covered
- Only the church scene was generated; the other reconstructions were checked by their up direction.
- The wall as a source of the up direction is covered by a synthetic test only; no real run chose it.
- Floor points on a slope or on stairs would tilt the scene. Not tested.
- Few photographs with camera poses estimated by the pipeline itself were not run; these runs use the benchmark poses.